Skip to content

syberalexis/linky-exporter

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

34 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

Linky-exporter

Build Status Go Report Card

This exporter get and expose French remote electrical information (Linky from EDF).

Summary

Install

From binary

Download binary from releases page

Example :

curl -L https://github.com/syberalexis/linky-exporter/releases/download/v3.0.0/linky-exporter-3.0.0-linux-amd64 -o /usr/local/bin/linky-exporter
chmod +x /usr/local/bin/linky-exporter
/usr/local/bin/linky-exporter

From docker

docker pull syberalexis/linky-exporter
docker run -d -p 9901:9901 -v /dev/serial0:/dev/serial0 syberalexis/linky-exporter:3.0.0 --device /dev/serial0

From sources

git clone git@github.com:syberalexis/linky-exporter.git
cd linky-exporter
go build cmd/linky-exporter/main.go -o linky-exporter
./linky-exporter --device /dev/serial0

or

git clone git@github.com:syberalexis/linky-exporter.git
cd linky-exporter
GOOS=linux GOARCH=amd64 VERSION=3.0.0 make clean build
./dist/linky-exporter-3.0.0-linux-amd64 --device /dev/serial0

Install as a service

In file /lib/systemd/system/linky_exporter.service :

Systemd

[Unit]
Description=Linky Exporter service
Wants=network-online.target
After=network-online.target

[Service]
Type=simple
ExecStart=/usr/local/bin/linky-exporter --device /dev/serial0
Restart=on-failure
RestartSec=5s

[Install]
WantedBy=multi-user.target
systemctl enable linky-exporter
systemctl start linky-exporter

OpenBSD

In file /etc/rc.d/linky_exporter :

#!/bin/ksh

daemon="/usr/local/bin/linky_exporter --device /dev/cuaU0" 
daemon_logger="daemon.info"
daemon_user="_nodeexporter"
. /etc/rc.d/rc.subr

pexp="${daemon}.*"
rc_bg=YES
rc_reload=NO

rc_cmd $1
usermod -G dialer _nodeexporter
chmod 555 /etc/rc.d/linky_exporter
rcctl enable linky_exporter

Help

usage: linky-exporter --device=DEVICE [<flags>]

| Parameters          | Default      | Description                                                                                                |
| ------------------- | ------------ | ---------------------------------------------------------------------------------------------------------- |
| --help              |              | Show context-sensitive                                                                                     |
| --version           |              | Show application version.                                                                                  |
| --debug             |              | Enable debug mode.                                                                                         |
| --address           | "0.0.0.0"    | Listen address                                                                                             |
| --port              | 9901         | Listen port                                                                                                |
| --auto              |              | Automatique mode                                                                                           |
| --historical        |              | Historical mode                                                                                            |
| --standard          |              | Standard mode                                                                                              |
| -d, --device=DEVICE |              | Device to read                                                                                             |
| -b, --baud=BAUD     | 1200         | Baud rate, 9600 for Standard, 1200 for Historical                                                          |
| --size=SIZE         |              | Serial frame size                                                                                          |
| --parity=PARITY     | "ParityNone" | Serial parity, Parity None = "N", Parity Odd = "O", Parity Even = "E", Parity Mark = M, Parity Space = "S" |
| --stopbits=STOPBITS | "Stop1"      | Serial stopbits, can be "Stop1", "1", "Stop1Half", "15", "Stop2", "2"                                      |

Metrics modes

Choose between the Historical and Standard mode

To find out on which mode your Linky is running on, you can check the configuration by pressing the + button until you reach the Mode TIC screen.

Examples

Historical

# HELP linky_energy Energie en Wh
# TYPE linky_energy counter
linky_energy{index="F1",linky_id="XXXX",mode="used"} 2.345675e+06
linky_energy{index="F2",linky_id="XXXX",mode="used"} 6.662251e+06
# HELP linky_energy_total Total Energie en Wh
# TYPE linky_energy_total counter
linky_energy_total{linky_id="XXXX",mode="used"} 9.007926e+06
# HELP linky_intensity Courant efficace en A
# TYPE linky_intensity gauge
linky_intensity{linky_id="XXXX",phase="1"} 11
# HELP linky_power Puissance apparente en VA
# TYPE linky_power gauge
linky_power{linky_id="XXXX",mode="used",phase="1"} 2530
# HELP linky_power_reference Puissance apparente de référence en kVA
# TYPE linky_power_reference counter
linky_power_reference{linky_id="XXXX",type="subscribed"} 6
# HELP linky_timestamp Synchronized timestamp in Linky
# TYPE linky_timestamp counter
linky_timestamp{contract="HC..",linky_id="XXXX",pricing="HP..",version="1"} 0
# HELP linky_voltage Tension efficace en V
# TYPE linky_voltage gauge

Standard

# HELP linky_energy Energie en Wh
# TYPE linky_energy counter
linky_energy{index="D1",linky_id="XXXX",mode="used"} 4.1585532e+07
linky_energy{index="F1",linky_id="XXXX",mode="used"} 4.1352473e+07
linky_energy{index="F2",linky_id="XXXX",mode="used"} 233059
# HELP linky_energy_total Total Energie en Wh
# TYPE linky_energy_total counter
linky_energy_total{linky_id="XXXX",mode="used"} 4.1585532e+07
# HELP linky_intensity Courant efficace en A
# TYPE linky_intensity gauge
linky_intensity{linky_id="XXXX",phase="1"} 6
# HELP linky_movable_peak Pointe mobile
# TYPE linky_movable_peak gauge
linky_movable_peak{linky_id="XXXX",phase="1",type="end"} 0
linky_movable_peak{linky_id="XXXX",phase="1",type="start"} 0
linky_movable_peak{linky_id="XXXX",phase="2",type="end"} 0
linky_movable_peak{linky_id="XXXX",phase="2",type="start"} 0
linky_movable_peak{linky_id="XXXX",phase="3",type="end"} 0
linky_movable_peak{linky_id="XXXX",phase="3",type="start"} 0
# HELP linky_power Puissance apparente en VA
# TYPE linky_power gauge
linky_power{linky_id="XXXX",mode="used",phase="1"} 1420
# HELP linky_power_last_year Puissance apparente n-1 en VA
# TYPE linky_power_last_year gauge
linky_power_last_year{linky_id="XXXX",mode="used",phase="1"} 3080
# HELP linky_power_max Puissance apparente en VA
# TYPE linky_power_max gauge
linky_power_max{linky_id="XXXX",mode="used",phase="1"} 2860
# HELP linky_power_reference Puissance apparente de référence en kVA
# TYPE linky_power_reference counter
linky_power_reference{linky_id="XXXX",type="breaking"} 6
linky_power_reference{linky_id="XXXX",type="subscribed"} 6
# HELP linky_status Statut issu du registre
# TYPE linky_status gauge
linky_status{linky_id="XXXX",name="Contact sec"} 0
linky_status{linky_id="XXXX",name="Couleur du jour pour le contrat historique tempo"} 0
linky_status{linky_id="XXXX",name="Couleur du lendemain pour le contrat historique tempo"} 0
linky_status{linky_id="XXXX",name="Dépassement de la puissance de référence"} 0
linky_status{linky_id="XXXX",name="Fonctionnement producteur/consommateur"} 0
linky_status{linky_id="XXXX",name="Mode dégradée de l horloge"} 0
linky_status{linky_id="XXXX",name="Organe de coupure"} 0
linky_status{linky_id="XXXX",name="Pointe mobile (PM)"} 0
linky_status{linky_id="XXXX",name="Préavis pointes mobiles"} 0
linky_status{linky_id="XXXX",name="Sens de l énergie active"} 0
linky_status{linky_id="XXXX",name="Statut du CPL"} 0
linky_status{linky_id="XXXX",name="Surtension sur une des phases"} 0
linky_status{linky_id="XXXX",name="Synchronisation CPL"} 0
linky_status{linky_id="XXXX",name="Tarif en cours sur le contrat distributeur"} 0
linky_status{linky_id="XXXX",name="Tarif en cours sur le contrat fourniture"} 0
linky_status{linky_id="XXXX",name="État de la sortie communication Euridis"} 0
linky_status{linky_id="XXXX",name="État de la sortie télé-information"} 0
linky_status{linky_id="XXXX",name="État du cache-bornes distributeur"} 0
# HELP linky_timestamp Timestamp en seconde
# TYPE linky_timestamp counter
linky_timestamp{contract="BASE",linky_id="XXXX",pricing="BASE",version="02"} 1668350147
# HELP linky_voltage Tension efficace en V
# TYPE linky_voltage gauge
linky_voltage{linky_id="XXXX",phase="1"} 229
# HELP linky_voltage_average Tension moyenne en V
# TYPE linky_voltage_average gauge
linky_voltage_average{linky_id="XXXX",phase="1"} 230

How to make all installation on Raspberry Pi Zero

Without USB on Linky

It's my case.

I followed this french tutorial https://www.jonathandupre.fr/articles/24-logiciel-scripts/208-suivi-consommation-electrique-compteur-edf-linky-avec-raspberry-pi-zero-w/
To use this exporter, you don't need install the PHP script, follow this.

And I bought this convertor https://www.tindie.com/products/Hallard/pitinfo/

With USB on Linky

If you have an USB on your Linky, follow this french tutorial https://sebastienreuiller.fr/blog/monitorer-son-compteur-linky-avec-grafana-cest-possible-et-ca-tourne-sur-un-raspberry-pi/

Good links