Expand Up @@ -92,11 +92,16 @@ Site information is entered in ``/HPXML/Building/Site``.
``Address/ZipCode`` string See [#]_ Yes ZIP Code where the home is located [#]_
===================== ======== ======= =========== ======== ======= ============================

.. [#] | For ENERGY STAR calculations, allowed StateCode choices depend on the ENERGY STAR version:
| - **National**: <anything>
| - **Pacific**: HI, GU, MP
| - **Florida**: FL
| - **OregonWashington**: OR, WA
.. [#] For ENERGY STAR calculations, allowed StateCode choices depend on the ENERGY STAR version:
\- **National**: <anything>
\- **Pacific**: HI, GU, MP
\- **Florida**: FL
\- **OregonWashington**: OR, WA
.. [#] ZipCode can be defined as the standard 5 number postal code, or it can have the additional 4 number code separated by a hyphen.
.. [#] ZipCode is only currently used to look up the eGrid subregion (see ``rulesets/data/egrid/ZIP_mappings.csv``) and Cambium region (see ``rulesets/data/cambium/ZIP_mappings.csv``) for emissions calculations and the CO2e Index.
Expand Down Expand Up @@ -172,17 +177,13 @@ One or more IECC climate zones are each entered as a ``/HPXML/Building/BuildingD
.. [#] The IECC climate zone for 2006 is always required.
Additional climate zones of other years may be required based on the programs selected for calculation:
=============================== =============
Program IECC ClimateZone Year Required
=============================== =============
IECC ERI 2015 2015
IECC ERI 2018 2018
IECC ERI 2021 2021
ENERGY STAR SFNH National v3.2 2021
ENERGY STAR MFNC National v1.2 2021
ZERH 1.0 2015
ZERH SF 2.0 2021
=============================== =============
\- **IECC ERI 2015**: 2015
\- **IECC ERI 2018**: 2018
\- **IECC ERI 2021**: 2021
\- **ENERGY STAR SFNH National v3.2**: 2021
\- **ENERGY STAR MFNC National v1.2**: 2021
\- **ZERH 1.0**: 2015
\- **ZERH SF 2.0**: 2021
.. [#] ClimateZone choices are "1A", "1B", "1C", "2A", "2B", "2C", "3A", "3B", "3C", "4A", "4B", "4C", "5A", "5B", "5C", "6A", "6B", "6C", "7", or "8".
Expand Down Expand Up @@ -736,9 +737,11 @@ If an in-unit boiler if specified, additional information is entered in ``Heatin
``ElectricAuxiliaryEnergy`` double kWh/yr >= 0 No See [#]_ Electric auxiliary energy
=========================== ======== ====== =========== ======== ======== =========================

.. [#] | If ElectricAuxiliaryEnergy not provided, defaults as follows:
| - **Oil boiler**: 330 kWh/yr
| - **Gas boiler**: 170 kWh/yr
.. [#] If ElectricAuxiliaryEnergy not provided, defaults as follows:
\- **Oil boiler**: 330 kWh/yr
\- **Gas boiler**: 170 kWh/yr
If instead a shared boiler is specified, additional information is entered in ``HeatingSystem``.

Expand Down Expand Up @@ -1059,9 +1062,12 @@ If an air-to-air heat pump is specified, additional information is entered in ``
If not a split system, provide SEER using the appropriate conversion factor.
.. [#] If HSPF2 provided, converted to HSPF using ANSI/RESNET/ICC 301-2022 Addendum C, where HSPF = HSPF2 / 0.85 (assumed to be a split system).
If not a split system, provide SEER using the appropriate conversion factor.
.. [#] | If neither extension/HeatingCapacityRetention nor HeatingCapacity17F provided, heating capacity retention defaults based on CompressorType:
| - **single/two stage**: 0.425 at 5F
| - **variable speed**: 0.5 at 5F
.. [#] If neither extension/HeatingCapacityRetention nor HeatingCapacity17F provided, heating capacity retention defaults based on CompressorType:
\- **single/two stage**: 0.425 at 5F
\- **variable speed**: 0.5 at 5F
.. [#] The extension/HeatingCapacityRetention input is a more flexible alternative to HeatingCapacity17F.
Either input approach can be used, but not both.
.. [#] If the fan power is not measured, a value of 0.58 W/cfm should be used according to ANSI/RESNET/ICC© 301-2019 Addendum B.
Expand Down Expand Up @@ -1629,10 +1635,13 @@ If a conventional storage water heater is specified, additional information is e
.. [#] If HeatingCapacity not provided, defaults based on Table 8 in the `2014 BAHSP <https://www.energy.gov/sites/prod/files/2014/03/f13/house_simulation_protocols_2014.pdf>`_.
.. [#] FirstHourRating only required if UniformEnergyFactor provided.
.. [#] RecoveryEfficiency must also be greater than the EnergyFactor (or UniformEnergyFactor).
.. [#] | If RecoveryEfficiency not provided, defaults as follows based on a regression analysis of `AHRI certified water heaters <https://www.ahridirectory.org/NewSearch?programId=24&searchTypeId=3>`_:
| - **Electric**: 0.98
| - **Non-electric, EnergyFactor < 0.75**: 0.252 * EnergyFactor + 0.608
| - **Non-electric, EnergyFactor >= 0.75**: 0.561 * EnergyFactor + 0.439
.. [#] If RecoveryEfficiency not provided, defaults as follows based on a regression analysis of `AHRI certified water heaters <https://www.ahridirectory.org/NewSearch?programId=24&searchTypeId=3>`_:
\- **Electric**: 0.98
\- **Non-electric, EnergyFactor < 0.75**: 0.252 * EnergyFactor + 0.608
\- **Non-electric, EnergyFactor >= 0.75**: 0.561 * EnergyFactor + 0.439
Tankless
~~~~~~~~
Expand Down Expand Up @@ -1901,19 +1910,30 @@ Many of the inputs are adopted from the `PVWatts model <https://pvwatts.nrel.gov
.. [#] Location choices are "ground" or "roof" mounted.
.. [#] ModuleType choices are "standard", "premium", or "thin film".
.. [#] Tracking choices are "fixed", "1-axis", "1-axis backtracked", or "2-axis".
.. [#] | System losses due to soiling, shading, snow, mismatch, wiring, degradation, etc.
| Default from the `PVWatts documentation <https://www.nrel.gov/docs/fy14osti/62641.pdf>`_ is 0.14, which breaks down as follows.
| Note that the total loss (14%) is not the sum of the individual losses but is calculated by multiplying the reduction due to each loss.
| - **Soiling**: 2%
| - **Shading**: 3%
| - **Snow**: 0%
| - **Mismatch**: 2%
| - **Wiring**: 2%
| - **Connections**: 0.5%
| - **Light-induced degradation**: 1.5%
| - **Nameplate rating**: 1%
| - **Age**: 0%
| - **Availability**: 3%
.. [#] System losses due to soiling, shading, snow, mismatch, wiring, degradation, etc.
Default from the `PVWatts documentation <https://www.nrel.gov/docs/fy14osti/62641.pdf>`_ is 0.14, which breaks down as follows.
Note that the total loss (14%) is not the sum of the individual losses but is calculated by multiplying the reduction due to each loss.
\- **Soiling**: 2%
\- **Shading**: 3%
\- **Snow**: 0%
\- **Mismatch**: 2%
\- **Wiring**: 2%
\- **Connections**: 0.5%
\- **Light-induced degradation**: 1.5%
\- **Nameplate rating**: 1%
\- **Age**: 0%
\- **Availability**: 3%
.. [#] AttachedToInverter must reference an ``Inverter``.
.. [#] NumberofBedroomsServed only required if IsSharedSystem is true, in which case it must be > NumberofBedrooms.
PV generation will be apportioned to the dwelling unit using its number of bedrooms divided by the total number of bedrooms served by the PV system.