Collective heat pump is not assigned any electricity on the input curve #1337

Open
mabijkerk opened this issue Apr 19, 2023 · 2 comments
Open
Assignees
Labels
Pinned Will never be marked as stale or auto-closed.

Comments

@mabijkerk
Copy link
Member

mabijkerk commented Apr 19, 2023

When I open the II3050v2 EUR scenario and add 7000 MW of the collective heat pump (energy_heat_heatpump_water_water_electricity), I get the following results:

Screenshot 2023-04-19 at 11 36 05

The collective heat pump is therefore producing steam hot water for the heat network and consuming electricity. However, when I export all the electricity curves, the input curve of the heat pump is 0 in every hour. This is confirmed in the following query:

SUM(V(energy_heat_heatpump_water_water_electricity,electricity_input_curve))

0.0

@noracato can you look into this issue? It does not seem to occur when I install 7000 MW in a blank nl2019 scenario:

SUM(V(energy_heat_heatpump_water_water_electricity,electricity_input_curve))

835,404.3176110185

The issue also does not seem to occur for any of the other electricity consumers on the heat network in the II3050v2 EUR scenario: energy_heat_well_geothermal, energy_heat_flexibility_p2h_heatpump_electricity and energy_heat_flexibility_p2h_boiler_electricity. These all have electricity assigned to the input curve. A difference is that these are must_run producers however, whereas the collective heat pump is the only dispatchable producer on the heat network that consumes electricity.

@noracato
Copy link
Member

noracato commented May 16, 2023

When I follow your steps of adding the 7000MW of collective heatpump, it starts showing up in the merit order:

Screenshot 2023-05-16 at 13 54 04

But it comes in place 3, after the waste heater with 0 capacity. Looking at the available capacity of the next candidate is, I believe, a stop condition for Merit. So maybe inside Merit the collective heat pump is never reached.

I'll look into this some more, but it might be a good starting point!

EDIT: no, moving it around in the merit order did nothing.

@github-actions
Copy link

This issue has had no activity for 60 days and will be closed in 7 days. Removing the "Stale" label or posting a comment will prevent it from being closed automatically. You can also add the "Pinned" label to ensure it isn't marked as stale in the future.

@github-actions github-actions bot added the Stale Issue had no activity for 60 days and will be, or has been, closed. label Jul 16, 2023
@mabijkerk mabijkerk added Pinned Will never be marked as stale or auto-closed. and removed Stale Issue had no activity for 60 days and will be, or has been, closed. labels Jul 17, 2023
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
Pinned Will never be marked as stale or auto-closed.
Projects
None yet
Development

No branches or pull requests

2 participants