OpenTelemetry Go Instrumentation - How it works

We aim to bring the automatic instrumentation experience found in languages like Java, Python and JavaScript to Go applications.

Design Goals

  • No code changes required - any Go application can be instrumented without modifying the source code.
  • Support wide range of Go applications - instrumentation is supported for Go version 1.12 and above. In addition, a common practice for Go applications is to shrink the binary size by stripping debug symbols via go build -ldflags "-s -w". This instrumentation works for stripped binaries as well.
  • Configuration is done via OTEL_* environment variables according to OpenTelemetry Environment Variable Specification. In order to inject instrumentation into your process, set the OTEL_GO_AUTO_TARGET_EXE environment variable to the path of the target executable. This is not a part of the OTEL specification mentioned above.
  • Instrumented libraries follow the OpenTelemetry specification and semantic conventions to produce standard OpenTelemetry data.

Why eBPF

Go is a compiled language. Unlike languages such as Java and Python, Go compiles natively to machine code. This makes it impossible to add additional code at runtime to instrument Go applications. Fortunately, the Linux kernel provides a mechanism to attach user-defined code to the execution of a process. This is called eBPF and it is widely used in other Cloud Native projects such as Cilium and Falco.

How it works

The Go auto-instrumentation agent runs as a single binary that analyzes a target Go process (the application you want to instrument) and attaches eBPF programs to hooks in the target process. To do this, the agent starts three objects internally:

  • A process Analyzer, which finds the target process and detects library functions that the agent can auto-instrument.
  • An OpenTelemetry Controller, which uses the OpenTelemetry Go SDK to export telemetry data.
  • An Instrumentation Manager, which coordinates sending events received from eBPF programs to the OpenTelemetry Controller.

The agent uses the Cillium eBPF libraries for Go to do much of the fundamental eBPF handling such as loading programs and reading events.

The Instrumentation object

The main entry point for the agent is the Instrumentation object, defined in instrumentation.go. This object coordinates the Controller, Manager, and Analyzer to orchestrate the auto-instrumentation of a process.

Finding the target process on the host

When the agent starts up, it first calls process.NewAnalyzer which creates the Analyzer object. The Analyzer then calls a.DiscoverProcessID(), which loops through the host's /proc directory to find a process matching the target binary's name.

Registering instrumentation function probes

Next, the Instrumentation object calls i.NewManager() to create a Manager object. The Manager object holds a map of the probed symbols, a channel to receive eBPF events, and a reference the the OpenTelemetry Controller to hand off parsed events and export telemetry.

Calling NewManager() uses m.registerProbes() to instantiate each instrumented library's Probe object.

Each Go library that is supported by the auto-instrumentation agent implements its own Probe. For example, the gRPC New() function does the following:

  • Creates an ID that uniquely identifies the Probe by its OpenTelemetry trace.SpanKind and package name.
  • Defines the probe.Const values to configure settings and define the relevant struct fields (and their offsets) for parsing telemetry data. Each Const is an object that implements the InjectOption() function to configure settings on the target process. For example, RegistersABIConst calls inject.WithRegistersABI().
  • Configures functions to attach Uprobes. Each function is represented by a probe.Uprobe object that holds the name of the function, the Cillium library call that will attach the eBPF program to the function, and an additional flag to indicate whether the Uprobe is optional.
  • Creates a ReaderFn that returns a Perf event reader from the Cillium libraries.
  • Creates a SpecFn that holds a reference the eBPF collection from the Cillium libraries.
  • Creates a ProcessFn that converts bytes to eBPF events.

Once each library's Probe object is created, the Manager calls m.registerProbe() on each one. This uses the Probe's Id to store a reference to the Probe in a map. In doing this, the Manager calls Manifest() on each Probe. This in turn calls NewManifest() that returns a Manifest object containing the Id, StructFields, and Symbols for the Probe.

Analyzing Go Process details

Next, the Instrumentation object calls analyzer.Analyze() to get the Go details and Modules (dependencies) for the target binary.

The Analyze() function first creates a TargetDetails object to hold information about the target process. By opening proc/{pid}/exe (using the PID it found earlier in DiscoverProcessID()), it can then read the Go build info, Go version, dependencies, and instrumentable functions in the process. When calling analyzer.Analyze(), the Instrumentation object passes manager.GetRelevantFuncs() as an argument. This function gets the list of Symbols from each Probe by checking its Manifest, telling Analyze() which functions to locate.

With the list of relevant functions, the Analyzer can call binary.FindFunctionsStripped() or binary.FindFunctionsUnStripped to get the exact location of the functions in the process (see Instrumentation Stability below for more details on this). Once it has that data, it returns a list of binary.Func objects for each relevant function.

The result of calling Analyze() is a TargetDetails object.

Allocating memory for eBPF maps

The Instrumentation object calls process.Allocate() to allocate memory for the agent to access eBPF maps. It does this by first calling ptrace.NewTracedProgram() to attach to the target process with ptrace. It then makes a number of syscalls to set up the eBPF map:

  • mmap to create the map
  • madvise to tell the kernel it will need to read this address soon
  • mlock to lock the address into RAM

The address of the map data is returned in an AllocationDetails object, which is stored in the TargetDetails built above.

Loading eBPF programs

With all of the initialization steps complete (analyzing the target process, finding relevant instrumentation points, allocating memory), the agent calls instrumentation.Run() to start the Instrumentation object. This calls manager.Run() and starts the Manager object within the Instrumentation.

The Manager mounts the target binary and calls bpffs.Mount() to create a subdirectory for the target executable under /sys/fs/bpf. It then calls probe.Load() on each registered Probe. At this point the inject options are applied to the target, and this is where offsets are loaded from the embedded JSON file with inject.WithOffset() (see Instrumentation Stability).

It then builds a Cillium CollectionSpec and calls LoadAndAssign() to load the eBPF map and program into the kernel. It analyzes the relevant Uprobes and stores their links.

After each Probe is loaded, they start separate goroutines with probe.Run(). This function will send Events out to the Manager on a channel called dest (or incomingEvents in the Manager).

Processing events

Each goroutine starts an infinite loop that blocks on a call to the Cillium reader.Read() function. This reads from the perf ring buffer when there are bytes available.

When an event is received, it is processed from byte data to an eBPF event by the Probe's ProcessFn (each instrumented library implements its own ProcessFn, as set during the New() call when the library was registered).

Exporting events

With the Probes running in their own goroutines, the Manager starts another loop listening on the m.incomingEvents channel for Events. When a Probe sends a processed Event out on its dest channel, the Manager receives it to the OpenTelemetry Controller object with c.Trace(). The Controller then uses the standard OpenTelemetry Go SDK to export the trace.

Main Challenges and How We Overcome Them

Using eBPF to instrument Go applications is non-trivial. In the following sections we will describe the main challenges and how we solved them.

Instrumentation Stability

eBPF programs access user code and variables by analyzing the stack and the CPU registers. For example, to read the value of the target field in the google.golang.org/grpc.ClientConn struct (see gRPC probe for an example), the eBPF program needs to know the offset of the field inside the struct. The offset is determined by the field location inside the struct definition.

Hard coding this offset information into the eBPF programs creates a very unstable instrumentation. Fields locations inside structs are subject to change and the eBPF program needs to be recompiled every time the struct definition changes. Luckily for us, there is a way to analyze the target binary and extract the required offsets, by using DWARF. The DWARF debug information is generated by the compiler and is stored inside the binary.

Notice that one of our design goals is to support stripped Go binaries - meaning binaries that do not contain debug information. In order to support stripped binaries and to create a stable instrumentation, we created a library called offsets-tracker. This library tracks the offset of different fields across versions.

We currently track instrumented structs inside the Go standard library and selected open source packages. This solution does not require DWARF information on the target binary and provides stability to instrumentations. Instrumentation authors can get a field location by name instead of hard coding a field offset.

The offsets-tracker generates the offset_results.json file. This file contains the offsets of the fields in the instrumented structs.

Uretprobes

One of the basic requirments of OpenTelemetry spans is to contain start timestamp and end timestamp. Getting those timestamps is possible by placing an eBPF code at the start and the end of the instrumented function. eBPF supports this requirement via uprobes and uretprobes. Uretprobes are used to invoke eBPF code at the end of the function. Unfortunately, uretprobes and Go do not play well together.

We overcome this issue by analyzing the target binary and detecting all the return statements in the instrumented functions. We then place a uprobe at the end of each return statement. This uprobe invokes the eBPF code that collects the end timestamp.

Timestamp tracking

eBPF programs can access the current timestamp by calling bpf_ktime_get_ns(). The value returned by this function is fetched from the CLOCK_MONOTONIC clock and represents the number of nanoseconds since the system boot time.

According to OpenTelemetry specification start time and end time should be timestamps and represent exact point in time. Converting from monotonic time to epoch timestamp is automatically handled by this library. Conversion is achieved by discovering the epoch boot time and adding it to the monotonic time collected by the eBPF program.

Support Go 1.17 and above

Since version 1.17 and above, Go changed the way it passes arguments to functions. Prior to version 1.17, Go placed arguments in the stack in the order they were defined in the function signature. Version 1.17 and above uses the machine registers to pass arguments.

We overcome this by analyzing the target binary and detecting the compiled Go version. If the compiled Go version is 1.17 or above, we read arguments from the machine registers. If the compiled Go version is below 1.17, we read arguments from the stack. This should be transparent to the instrumentation authors and abstracted by a function named get_argument().