Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Shouldn't it continue when failed to decode a msg when consuming from the input protobuf stream #2

Open
fivesheep opened this issue Mar 10, 2018 · 1 comment

Comments

@fivesheep
Copy link

For this piece of code, when dec.ReadMsg has error and the error is not io.EOF, shall it skip to the next iteration with continue after the line a new decoder was created?

https://github.com/cpuguy83/docker-log-driver-test/blob/master/driver.go#L95-L102

	for {
		if err := dec.ReadMsg(&buf); err != nil {
			if err == io.EOF {
				logrus.WithField("id", lf.info.ContainerID).WithError(err).Debug("shutting down log logger")
				lf.stream.Close()
				return
			}
			dec = protoio.NewUint32DelimitedReader(lf.stream, binary.BigEndian, 1e6)
		}
		var msg logger.Message
		msg.Line = buf.Line
		msg.Source = buf.Source
		msg.Partial = buf.Partial
		msg.Timestamp = time.Unix(0, buf.TimeNano)

		if err := lf.l.Log(&msg); err != nil {
			logrus.WithField("id", lf.info.ContainerID).WithError(err).WithField("message", msg).Error("error writing log message")
			continue
		}

		buf.Reset()
}
@cpuguy83
Copy link
Owner

Indeed it should.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment