Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We鈥檒l occasionally send you account related emails.

Already on GitHub? Sign in to your account

Wrong aggregation of Precision\Recall\F1-Score #2394

Open
silvanobianchi opened this issue Feb 20, 2024 · 2 comments
Open

Wrong aggregation of Precision\Recall\F1-Score #2394

silvanobianchi opened this issue Feb 20, 2024 · 2 comments
Assignees
Labels
help wanted Extra attention is needed waiting on author

Comments

@silvanobianchi
Copy link

馃悰 Bug

I am training a binary classifier and am monitoring the following metrics: precision, recall, accuracy, F1 score.

During validation phase, the dataloader loads N batches where the samples all belong to class 0, and then M batches where the samples belong to class 1.

The aggregate accuracy that is calculated at the end of the epoch is identical to what I get from my script, while Precision and Recall are wrong.

This behaviour occurs for Precision, Recall, F1-Score, which have about half the value they should have: Accuracy 0.9 while these values have 0.55
I think the problem is due to the fact that the first N batches have Precision-Recall around 0 because they have no positive class samples, while the other M batches have around 1 because they only have positive class samples and when I aggregate these results I get a value of around 0.5.

I am monitoring these values with BinaryPrecision, BinaryRecall, BinaryF1Score.

Do you know what could be the problem? I think there is something strange in the aggregation of these metrics

@silvanobianchi silvanobianchi added bug / fix Something isn't working help wanted Extra attention is needed labels Feb 20, 2024
Copy link

Hi! thanks for your contribution!, great first issue!

@SkafteNicki
Copy link
Member

Hi @silvanobianchi , thanks for reporting this issue.
This sound very strange to me. Regardless of how data is feed into the metrics, the correct result should still be calculated. Here is an example where all data is feed in as one batch vs. doing it over multiple batches. Also note that the labels are split in the way you describe:

import torch
from torchmetrics import MetricCollection
from torchmetrics.classification import BinaryPrecision, BinaryRecall, BinaryAccuracy

preds = torch.randint(2, (1000,))
target = torch.cat([torch.zeros(500), torch.ones(500)], dim=0)

# all as one batch
metrics = MetricCollection(BinaryAccuracy(), BinaryPrecision(), BinaryRecall())
print(metrics(preds, target))

# as separate batches
metrics = MetricCollection(BinaryAccuracy(), BinaryPrecision(), BinaryRecall())
for p, t in zip(preds.split(10), target.split(10)):
    metrics.update(p, t)
print(metrics.compute())

if you run the above it will output the exact same in both cases.