mqtt:
host: 192.168.1.2
port: 1883
devices:
# My relays control mostly lights, so I use "light" type by default
x-relay: &default-relay
exclude_controls:
- "^Input \\d+ (counter|freq)$" # These values have no practical value to me
controls: &default-relay-controls
K1:
force_type: light
K2:
force_type: light
K3:
force_type: light
K4:
force_type: light
K5:
force_type: light
K6:
force_type: light
wb-mr3_27: *default-relay
wb-mr3_32: *default-relay
wb-mr6c_11:
<<: *default-relay
controls:
<<: *default-relay-controls
K6:
force_type: fan
wb-mr6c_19:
<<: *default-relay
controls:
<<: *default-relay-controls
K5:
force_type: fan
wb-map6s_20:
exclude_controls:
- "^.* [1-6]$" # I don't have any MAP6S inputs connected right now
controls:
Frequency:
overrides:
unit_of_measurement: Hz